Be the first to review this product
- Reliably handle a wide range of high-current applications with 2000 A ac + dc true-rms, 1400 A ac, and 2000 A dc
- The large 58 mm (2.3 in) jaw capacity is suitable for large or multiple conductors
- CAT IV 600 V, CAT III 1000 V rating for added user protection
- In-rush current measurement captures ‘power-on’ surge current with accuracy and repeatability
- High voltage measurement of 1000 V ac + dc true-rms, 600 V ac, and 1000 V dc allows the user to perform multiple tests with only one tool (355 only)
- Resistance to 400K ohms coupled with a continuity beeper provide the convenience of a multimeter in a clamp meter. (355 only)
- Accurately measure frequency up to 1 kHz for optimum troubleshooting
- Quickly analyze readings using the MIN, MAX, and AVG functions
- A large backlit display allows for easy visibility in low-lit areas
- Use the display hold feature to capture readings even when the display cannot be viewed
- Use the low-pass filter to smooth out noisy loads and stabilize readings
You may also be interested in the following product(s)
| Product Includes |
* 353 clamp meter * C43 Soft carrying case * 6 AA batteries * User manual * 3 year warranty |
| Specifications |
| Electrical specifications |
| Current measurement dc and ac 10 Hz to 100 Hz |
| Range : 40 A |
Resolution: 10 mA
Accuracy, A: 1.5 % rdg + 15 digits
Trigger Level for Inrush: 0.50 A
Trigger Level for Hz Filter OFF: 2.50 A
Trigger Level for Hz Filter ON: 0.50 A |
| Range : 400 A |
Resolution: 100 mA
Accuracy, A: 1.5 % rdg + 5 digits
Trigger Level for Inrush: 5.0 A
Trigger Level for Hz Filter OFF: 2.5 A
Trigger Level for Hz Filter ON: 2.5 A |
| Range : 2000 A; 1400 ac rms |
Resolution: 1 A
Accuracy, A: 1.5 % rdg + 5 digits
Trigger Level for Inrush: 5 A
Trigger Level for Hz Filter OFF: 8 A
Trigger Level for Hz Filter ON: 8 A |
|
| Crest Factor (50/60 Hz) |
| Range : 40 A |
Crest Factor* : 2 @ 33 A, 2.4 @ 27 A |
| Range : 400 A |
Crest Factor* : 2 @ 330 A, 2.4 @ 270 A |
| Range : 2000 A; 1400 ac rms |
Crest Factor* : 2 @ 1000 A, 2.4 @ 833 A |
|
| Current measurement ac 100.1 Hz to 1 kHz |
| Range : 40 A |
Resolution: 10 mA
Accuracy > 10 A : 3.5 % rdg + 15 digits
Trigger Level for Inrush: 0.50 A
Trigger Level for Hz Filter OFF : 2.50 A
Trigger Level for Hz Filter ON : 0.50 A |
| Range : 400 A |
Resolution: 100 mA
Accuracy > 10 A : 3.5 % rdg + 5 digits
Trigger Level for Inrush: 5.0 A
Trigger Level for Hz Filter OFF : 2.5 A
Trigger Level for Hz Filter ON : 2.5 A |
| Range : 2000 A; 1400 ac rms |
Resolution: 1 A
Accuracy > 10 A : 3.5 % rdg + 5 digits
Trigger Level for Inrush: 5 A
Trigger Level for Hz Filter OFF : 8 A
Trigger Level for Hz Filter ON : 8 A |
|
| Frequency measurement |
| Measurement range |
5.0 Hz to 1 kHz |
| Resolution |
0.1 Hz (15 Hz to 399.9 Hz); 1 Hz (400 Hz to 1 kHz) |
| Accuracy – 5.0 Hz to 100 Hz |
0.2 % + 2 counts |
| Accuracy – 100.1 Hz to 1 kHz |
0.5 % + 5 counts |
| Trigger level |
Refer to current and voltage tables |
|
| General specifications |
| Batteries |
| |
Six 1.5 V AA NEDA 15 A or IEC LR6 |
|
| Battery life (with typical usage, backlight off) |
|
| Test leads |
|
| Weight |
|
| Jaw size |
|
| Dimensions (LxWxD) |
| |
300 mm x 98 mm x 52 mm (12 in x 3.75 in x 2 in) |
|
| Safety rating |
| |
IEC 61010-2-032, 600 V CAT IV, 1000 V CAT III |
|
| Environmental specifications |
| Operating temperature |
| |
32 °F to + 122 °F (0 °C to +50 °C) |
|
| Storage temperature |
| |
-4 °F to 140 °F (-20 °C to +60 °C) |
|
| Operating humidity |
| |
0 to 95 % (non-condensing) |
|
| Operating altitude |
|
| Storage altitude |
|
| IP rating |
|
| Drop test requirements |
|
| EMI, RFI, EMC |
| |
FCC part 15, IEC/EN 61326-1:1997 class B, IEC/EN 61326:1997 3V/m, performance criteria B, EN61325 |
|
| Temperature coefficients |
| Current: |
0.1 % of reading per °C outside 22 °C to 24 °C |
| Voltage: |
0.1 % of reading per °C outside 22 °C to 24 °C |
|
|
| size |
300 mm x 98 mm x 52 mm (12 in x 3.75 in x 2 in) |
| Shipping Weight |
3.7500 |
| Power Supply |
Six 1.5 V AA NEDA 15 A or IEC LR6 |
| Manufacturer |
Fluke |
| Manufacturer Model Number |
2840252 |
| Manufacturer Warranty |
Three Years |
| upc code |
0 95969 40119 7 |